ZPM - Differential pressure transmitter multi sensor IP66 (HIGH ACCURACY)
BAPI’s ZPM in a BAPI-Box is designed for quick and easy field installation. Output, range and other variables are quickly set in the field without powering the unit. LEDs on the face of the unit indicate when the pressure is low, in range or high for line-of-sight troubleshooting without accessing the BAS. Ranges and Outputs are set in the field for this unit rather than at the time of order.
- IP66 or NEMA 4-Rated Enclosure
- 10 Field Selectable Pressure Ranges and 5 Field Selectable Outputs
- Ranges and Outputs Can Be Set Without Powering the Unit
- Low, Standard and High Ranges Units
- Display shows the actual pressure value even if it exceeds your selected range
- NIST Certificate Included with Each Unit at No Extra Charge


VISA/MASTERCARD, PAYPAL,
ANTICIPATED REMITTANCE OR DIRECT
PAYMENT WITH DELIVERY AT OUR
WHAREHOUSE.
CUSTOMER SERVICE: +39.02.6659.5982
SKU | Model | Description | Price | Quantity | ||
---|---|---|---|---|---|---|
![]() |
42972 | BA/ZPM-SR-ST-D-BB | Display: YES. |
315 EUR |
Description
MEDIA:
Clean, dry, non-corrosive gases
POWER:
7 to 40 VDC (4 to 20 mA output)
7 to 40 VDC or 18 to 32 VAC (0 to 5 or 1 to 5 V output)
13 to 40 VDC or 18 to 32 VAC (0 to 10 or 2 to 10 V output)
POWER CONSUMPTION:
20 mA max, DC only at 4 to 20 mA output
4.9 mA max DC at 0 to 5 VDC or 0 to 10 VDC output
0.12 VA max AC at 0 to 5 VDC or 0 to 10 VDC output
LOAD RESISTANCE:
4 to 20 mA Output 850 Ω maximum @ 24 VDC, 0 to 5 V or 0 to 10 V output 6K
to 10KΩ minimum
STABILITY:
±0.25% Full Scale per year
ENVIRONMENTAL OPERATING RANGE:
Temperature: -20 to 60°C
STORAGE TEMPERATURE:
-40 to 85°C
OVERPRESSURE:
Proof: 75kPa, Burst: 128kPa
HUMIDITY:
0 to 95% RH, non-condensing
PORT SIZE:
1/4" barbed
ENCLOSURE MATERIAL:
UV-resistant polycarbonate UL94, V-0
ACCURACY FOR STANDARD PRESSURE RANGES AT 22°C:
±0.25% of range
ACCURACY FOR LOW PRESSURE RANGES AT 22°C:
±0.5% of range for the three lowest unidirectional and bidirectional ranges
±0.25% of range all other ranges
ACCURACY FOR HIGH PRESSURE RANGES AT 22°C:
±0.25% on all ranges
WIRING:
2 wires (4 to 20mA Current loop)*, 3 wires (AC or DC powered, Voltage out)
Documentation
Accessories
SKU | Model | Description | Price | Quantity | ||
---|---|---|---|---|---|---|
![]() |
18172
|
Differential Pressure Certificate Ref. UKAS/ACCREDIA |
UKAS/ACCREDIA Traceable Certificate for DIFFERENTIAL PRESSURE on 3-point check: low range, mid-scale, full scale. |
€35.00
|