VISION 1000-2000-3000 - Low cost turbine with pulse output

Economical turbines for low viscosity and non-aggressive liquids.
High resolution thanks to the high number of pulses. The simple mechanical construction of the Vision sensor guarantees long life without loss of precision.

Read more


VISA/MASTERCARD, PAYPAL,
ANTICIPATED REMITTANCE OR DIRECT
PAYMENT WITH DELIVERY AT OUR
WHAREHOUSE.



CUSTOMER SERVICE: +39.02.6659.5982

SKU Model Description Price Quantity Price for quantity
33600 2008 56500-165-2F66-2

Flow rate: 0.5 - 7.5 l / min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 4700 pulses / liter
Electrical connection: 2 mt cable
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

56 EUR
1 - 2 : € 56.00
3 - 5 : € 50.40
6 - 14 : € 42.00
15 - 24 : € 39.20
25 - 49 : € 36.40
50 - 99 : € 33.60
33601 2008 56500-165-4F44-2

Flow rate: 1 - 15 l / min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 2200 pulses / liter
Electrical connection: 2 mt cable
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

56 EUR
1 - 2 : € 56.00
3 - 5 : € 50.40
6 - 14 : € 42.00
15 - 24 : € 39.20
25 - 49 : € 36.40
50 - 99 : € 33.60
33602 2008 56500-165-4F22-2

Flow rate: 1 - 25 l / min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 1000 pulses / liter
Electrical connection: 2 mt cable
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

56 EUR
1 - 2 : € 56.00
3 - 5 : € 50.40
6 - 14 : € 42.00
15 - 24 : € 39.20
25 - 49 : € 36.40
50 - 99 : € 33.60
33603 2008 56500-165-4F17-2

Flow rate: 2 - 35 l / min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 750 pulses / liter
Electrical connection: 2 mt cable
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

56 EUR
1 - 2 : € 56.00
3 - 5 : € 50.40
6 - 14 : € 42.00
15 - 24 : € 39.20
25 - 49 : € 36.40
50 - 99 : € 33.60
30079 1005 2F66- 56547-163-2F66

Flow rate: 0.1 - 2.5 l / min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 1/4 "G male
Accuracy ± 3% .V.L. k factor: about 22,000 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

58 EUR
1 - 2 : € 58.00
3 - 5 : € 52.20
6 - 14 : € 43.50
15 - 24 : € 40.60
25 - 49 : € 37.70
50 - 99 : € 34.80
30080 2006 2F66- DIN 56510-163-2F66

Flow rate: 0,5 – 5 l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 6900 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

55 EUR
1 - 2 : € 55.00
3 - 5 : € 49.50
6 - 14 : € 41.25
15 - 24 : € 38.50
25 - 49 : € 35.75
50 - 99 : € 33.00
30081 2008 4F44- DIN 56500-163-4F44

Flow rate: 1 – 15 l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 2200 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

55 EUR
1 - 2 : € 55.00
3 - 5 : € 49.50
6 - 14 : € 41.25
15 - 24 : € 38.50
25 - 49 : € 35.75
50 - 99 : € 33.00
30082 2008 4F17- DIN 56500-163-4F17

Flow rate: 2 – 35 l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 750 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

56 EUR
1 - 2 : € 56.00
3 - 5 : € 50.40
6 - 14 : € 42.00
15 - 24 : € 39.20
25 - 49 : € 36.40
50 - 99 : € 33.60
30087 3012 4F16- DIN 56422-163-4F16

Flow rate: 5 – 65 l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Trogamid
Threaded connections 3/4 "G male
Accuracy ± 3% .V.L. k factor: about 210 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

118 EUR
1 - 2 : € 118.00
3 - 5 : € 106.20
6 - 14 : € 88.50
15 - 24 : € 82.60
25 - 49 : € 76.70
50 - 99 : € 70.80
30086 2008 2F66- DIN 47000-163-2F66

Flow rate: 2 – 8  l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Brass
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 4200 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

123 EUR
1 - 2 : € 123.00
3 - 5 : € 110.70
6 - 14 : € 92.25
15 - 24 : € 86.10
25 - 49 : € 79.95
50 - 99 : € 73.80
30085 2008 4F22- DIN 47000-163-4F22

Flow rate: 3 – 25 l/min
Temperature -20 ... 100 ° C.
Max pressure: 25 bar.
Material: Brass
Threaded connections 3/8 "G male
Accuracy ± 3% .V.L. k factor: about 920 pulses / liter
Electrical connection: MICRO-EN mini din connector
Signal output: open collector pulses (NPN sinking)
Max current: 20 mA
Pull-up resistor: 1 - 2.2 kOhm

123 EUR
1 - 2 : € 123.00
3 - 5 : € 110.70
6 - 14 : € 92.25
15 - 24 : € 86.10
25 - 49 : € 79.95
50 - 99 : € 73.80

Description

The Vision series turbines are suitable for precise measurement of small quantities of liquids.
High resolution thanks to the high number of pulses., Response time is very short. The simple mechanical construction of the Vision sensor guarantees long life without loss of precision. Pressure peaks do not affect the measurement.

Measurement principle

The rotor is activated by the force of the fluid in proportion to the flow. A Hall effect generator supplies pulses, the generated pulses are specified as kfactor.

Documentation

Similar products

FHKU - Low cost turbines

Low cost turbines for general applications for measurements of non-viscous and clean liquids. Flow rate defined by the nozzle used. Accuracy: +/- 2% Repeatability: +/- 0.25%

FH - Low cost brass turbine

Low cost turbine for general applications for measurements of non-viscous and clean liquids. Flow rate defined by the nozzle used. Entrance and exit positioned on the same side.

FHKSC - Low cost plastic turbine for water

Small turbine for general applications designed mainly for coffee machines for domestic and non-domestic use. Thanks to its closing system the outlet nozzle can be positioned in 4 different positions.