SGE-25 - HYDROSTATIC LEVEL PROBES
The level probe designed for level measurements in tanks, wells and piezometers.
The sensor measures the liquid level based on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure.


VISA/MASTERCARD, PAYPAL,
ANTICIPATED REMITTANCE OR DIRECT
PAYMENT WITH DELIVERY AT OUR
WHAREHOUSE.
CUSTOMER SERVICE: +39.02.6659.5982
SKU | Model | Description | Price | Quantity | ||
---|---|---|---|---|---|---|
![]() |
37908 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-1 M/L5 | Hydrostatic level probe |
257 EUR | ||
![]() |
11134 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-2 M/L6 | Hydrostatic level probe |
262 EUR | ||
![]() |
8919 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-4 M/L10 | Hydrostatic level probe |
270 EUR | ||
![]() |
8099 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-6 M/L10 | Hydrostatic level probe |
270 EUR | ||
![]() |
5141 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-10 M/L15 | Hydrostatic level probe |
285 EUR | ||
![]() |
9078 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-10 M/L20 | Hydrostatic level probe |
296 EUR | ||
![]() |
8308 | SGE-25 - HYDROSTATIC LEVEL PROBES - SGE-25/0-20 M/L30 | Hydrostatic level probe |
320 EUR |
Description
The SGE-25 Hydrostatic level probe is applicable to measure liquid levels in tanks, deep wells or piezometers. The probe measures liquid levels, basing on a simple relationship between the height of the liquid column and the resulting hydrostatic pressure. The pressure measurement is carried out on the level of the separating diaphragm of the immersed probe and is related to atmospheric pressure through a capillary in the cable. when lowered to the reference level , the probe may either hang freely on the cable or lie on the bottom of the tank, The cable with the capillary can be extended using a standard signal cable. The cable connection should be situated in a non hermetically sealed box (The internal pressure inside the box should be equal to the atmospheric pressure), preventing water or other contaminats from getting in to the capillary.
SPECIFICATIONS:
Overpressure : ranges 1 m H2O (40 x range) ranges up to 4 m H2O ( 25 x range) ranges up to 500 m H2O (10 x range max 700m)
Accuracy (BFSL) : 0...1 mH2O : 0,3% f.s. 0....4m H2O : 0,15% f.s. 0....10 mH2O 0...500 mH2O 0,1% f.s.
Thermal error : typical 0,3%/10° C (up to 4 m/H2O) typical 0,2%/10° C (up to 500 m/H2O)
Compensated temperature range: 0 ....25°C
Fluid temperature: -25....+50° C for ranges > 20 m/H2O -25.....+75°C for ranges< 20 m/H2O
Output : 4-20 mA
Power supply: 10,5 - 36 Vcc
Rating: IP 68
Cable Material : polyurethane
Probe Material: 316 L SS
Diaphragm material: Hastelloy C276