BASIS Small Flow Meter for air and gas
Compact MEMS Thermal Mass Flow Meters
These small mass flow meters offer the performance of a premier product for processes with space constraints. These devices fit in the palm of your hand but are built to last.
• Accurate flow control in a compact, durable, metal flow body
• Run sophisticated flow-control scripts using a fast, robust Alicat ASCII command set
• Dispense doses and batches with built-in totalizer
• Switch between 9 gases: air, N2, O2, CH4, He, H2, Ar, CO2, N2O (via software BC-EVALKIT)
• 0.1-100% of full scale measurement and control range (1,000:1 turndown)


VISA/MASTERCARD, PAYPAL,
ANTICIPATED REMITTANCE OR DIRECT
PAYMENT WITH DELIVERY AT OUR
WHAREHOUSE.
CUSTOMER SERVICE: +39.02.6659.5982
| SKU | Model | Description | Price | Quantity | Price for quantity | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 47073 | B-100C-N2C00A-0000 | Flow range: 0-100 SCCM |
700 EUR |
|
|||||||||||
| 47074 | B-500C-N2C00A-0000 | Flow range: 0-500 SCCM |
700 EUR |
|
|||||||||||
| 47075 | B-005L-N2C00A-0000 | Flow range: 0-5 SLPM |
700 EUR |
|
|||||||||||
| 47076 | B-010L-N2C00A-0000 | Flow range: 0-10 SLPM |
700 EUR |
|
|||||||||||
| 47077 | B-020L-N2C00A-0000 | Flow range: 0-20 SLPM |
700 EUR |
|
|||||||||||
| 47078 | B-100L-N2C00A-0000 | Flow range: 0-100 SLPM |
780 EUR |
|
|||||||||||
| 46510 | GH6-61 | Power supply cable for BASIS flowmeter |
20 EUR |
|
|||||||||||
| 47079 | BC-EVALKIT | Power and Comms for BASIS |
120 EUR |
|
Description
SPECIFICATIONS
Flow repeatability (2σ) ± 0.25% reading or ± 0.05% of full scale
Control and measurement range 0.1% – 100% of full scale (1,000:1 turndown ratio)
Temperature sensitivity Mass flow zero and span shift: ± 0.05% of reading per °C from calibration conditions
Temperature accuracy ± 1.5 °C
Operating temperature range 0 – 50°C (ambient and gas)
Operating pressure range: see datasheet
Totalizer volume uncertainty ± 0.6% of reading in additional uncertainty
Typical control response time As fast as 100 ms (T63), flow rate dependent, user-adjustable
Typical indication response time < 6 ms, flow rate dependent
Typical warm-up time 1 minute (5 minutes optimal)
Digital input and output options RS-232 or RS-485
Digital data update rate As fast as 176 Hz, baud rate and system dependent
Analog input and output 0-5Vdc or 4-20mA
Analog update rate 400 Hz
Analog signal accuracy ± 0.125% of full scale additional uncertainty Hz
Electrical connection 6-pin JST GH
Power requirements Controller: 12–24 Vdc, 210 mA
Meter: 12–24 Vdc, 12 mA